Every acronym and technical term you might see on a quote, spec sheet or savings calculator — covering solar panels, air source and ground source heat pumps, and the grants and paperwork along the way. Figures correct as of August 2026; grant amounts, VAT rates and tariffs change periodically, so always check the current position with us before relying on a number.

Solar panel (Solar PV) terms

Everything on a solar quote, in plain English

Array
The full set of solar panels installed together, usually all on one roof.
Battery storage (home battery)
A unit that stores surplus solar electricity generated during the day so you can use it in the evening instead of exporting it cheaply and buying it back at a higher price.
DNO (Distribution Network Operator)
The company that owns and runs the local electricity wires in your area (different from your energy supplier). Larger solar systems need DNO permission before being connected.
EPC (Energy Performance Certificate)
A certificate rating a property's energy efficiency from A to G. Solar and heat pumps typically improve a home's EPC rating, which can matter for mortgages, lettings and resale.
Export tariff
The rate you're paid for electricity your panels generate but you don't use yourself, which flows back to the grid. In the UK this is paid under the Smart Export Guarantee (SEG).
Feed-in Tariff (FIT)
The government scheme that paid homeowners for solar generation before 2019. It's closed to new applicants — SEG replaced it — but some older systems are still on FIT contracts.
G98 / G99
Standard forms your installer files with your DNO to notify or seek approval for connecting a generator (like solar panels) to the local electricity network. G98 covers small systems; G99 covers larger ones.
Generation factor (kWh/kWp)
How many units of electricity a 1 kWp system produces in a year at your specific location. The UK average is around 900 kWh/kWp/yr, ranging from about 720 in Scotland to 1,000+ in the South West.
Grid-tied
A solar system connected to the mains electricity grid, so you can draw extra power when you need it and export surplus power when you don't. The vast majority of UK domestic solar systems are grid-tied.
Inverter
The box that converts the DC electricity your panels produce into the AC electricity your home and the grid actually use. It's the part most likely to need replacing during a system's lifetime, typically after 10–15 years.
kWh (kilowatt-hour)
A unit of energy — the amount used by a 1,000-watt appliance running for one hour. It's what you're billed for on your electricity bill and what solar panels generate.
kWp (kilowatt-peak)
The maximum output a solar system can produce under ideal conditions — think of it as the size or “engine capacity” of the system. A typical UK home suits a 3.5–6 kWp array.
MCS (Microgeneration Certification Scheme)
The UK quality standard for small-scale renewable installations, including solar and heat pumps. MCS certification is usually required to qualify for grants like the Boiler Upgrade Scheme, and confirms the installer and equipment meet recognised standards.
Panel degradation
The gradual, small loss of efficiency solar panels experience over time — typically around 0.5% per year, so a panel might still produce roughly 88% of its original output after 25 years.
Payback period
How many years of savings and export income it takes to recoup the upfront cost of a system.
Self-consumption
The share of the electricity your panels generate that you use directly in your home, rather than exporting it. Using it directly is worth more than exporting it, because you avoid the full price of buying it from the grid.
Self-sufficiency
How much of your total electricity use (not just generation) is met by your own solar and battery, rather than the grid — distinct from self-consumption, which measures the other direction.
SEG (Smart Export Guarantee)
The UK government scheme requiring electricity suppliers to pay households for solar electricity exported to the grid. Rates vary a lot between suppliers, roughly 4p–16p per unit.
Smart tariff / time-of-use tariff
An electricity tariff charging different rates at different times of day — cheap overnight, pricier at peak times — that can be combined with a battery to shift more of your usage to the cheapest hours.
Heat pump terms (ASHP & GSHP)

Air source and ground source heat pumps, explained

ASHP (Air Source Heat Pump)
A heat pump that extracts heat from the outside air, even in cold weather, to heat your home and hot water. The more common and cheaper of the two main types, typically £8,000–£18,000 installed before any grant.
Buffer tank
A water tank that helps a heat pump run smoothly and efficiently by giving it a minimum volume of water to work with, reducing how often it switches on and off.
COP (Coefficient of Performance)
A snapshot measure of a heat pump's efficiency at a single moment — for example, a COP of 3 means it produces 3 units of heat for every 1 unit of electricity it uses. See also SCOP, which is the more useful year-round figure.
Defrost cycle
A brief process where an air source heat pump reverses to melt ice that builds up on its outdoor unit in cold, damp weather. It temporarily reduces efficiency but is normal operation.
Degree days
A measure of how cold a period has been, used by engineers to estimate a building's heating demand — more degree days means more heating was needed.
Emitters
The general term for whatever releases heat into your rooms — radiators or underfloor heating. Heat pumps often need larger radiators (or underfloor heating) than a gas boiler because they work best at lower temperatures.
Flow temperature
The temperature of the water leaving the heat pump on its way to your radiators or underfloor heating. Lower flow temperatures (35–45°C, versus 60–70°C for an old gas boiler) are more efficient for a heat pump — this is the single biggest factor a good installer controls.
GSHP (Ground Source Heat Pump)
A heat pump that extracts heat from the ground via buried pipes, which stay at a fairly constant temperature year-round. Usually more efficient than an ASHP but significantly more expensive to install (roughly £16,000–£31,000) because of the groundworks involved.
Ground loop
The network of pipes buried in the ground for a GSHP, through which fluid circulates to collect heat from the earth. Can be laid horizontally in trenches (cheaper, needs more land) or vertically in a borehole (pricier, needs less space).
Heat loss / heat loss survey
An assessment of how quickly a building loses heat through its walls, windows, roof and floor, used to correctly size a heat pump and its radiators. A proper room-by-room heat loss survey is the foundation of a well-designed system.
Monobloc vs split system
Two ways an ASHP can be built: a monobloc has all the refrigerant components in the outdoor unit (simpler, more common); a split system has some components outside and some inside, requiring a specialist to handle refrigerant on site.
Refrigerant
The fluid inside a heat pump that absorbs heat at low temperature and releases it at high temperature, which is how the whole system works. Modern systems increasingly use lower-impact refrigerants as regulations tighten.
SCOP (Seasonal Coefficient of Performance)
The average efficiency of a heat pump across a full year, accounting for seasonal weather changes — a more realistic figure than COP. A well-designed system might achieve a SCOP of 4.0+, while a poorly designed one might only reach 2.8, which is why installer quality matters as much as the equipment.
Unvented cylinder
A pressurised hot water tank fed directly from the mains, commonly installed alongside a heat pump to store hot water — different from the older “vented” tanks fed from a loft cistern.
Weather compensation
A control feature that automatically adjusts a heat pump's flow temperature based on the outside temperature, so it runs no hotter than it needs to — improving efficiency.
Zoning / zone valves
Splitting a heating system into separate areas (e.g. upstairs/downstairs) that can be controlled independently, using valves to direct hot water only where it's needed.
Grants, bills & paperwork

Terms you'll see on quotes, invoices and grant paperwork

BUS (Boiler Upgrade Scheme)
The main UK government grant for heat pumps: £7,500 off an air or ground source heat pump in England and Wales, or £9,000 for eligible off-gas-grid oil/LPG homes (a temporary uplift running 21 July 2026 to 31 March 2027). Your installer applies it on your behalf and deducts it from your bill.
Deposit / balance
Most installers take a deposit on order and the remaining balance on completion. Because the installer usually has to front the BUS grant amount and reclaim it from Ofgem afterwards, ask how this affects your payment schedule.
EPC (Energy Performance Certificate)
See Solar Terms above — the same certificate applies whether you're installing solar, a heat pump, or both.
Grant
Government (or sometimes local authority) funding that reduces the cost of installing solar or a heat pump. The main current one for heat pumps is the Boiler Upgrade Scheme (BUS); solar panels do not currently have an equivalent capital grant, though VAT relief applies to both.
MCS certification
See Solar Terms above — required for both solar and heat pump installations to qualify for most grants and to demonstrate the work meets recognised quality standards.
Ofgem price cap
The maximum price per unit that UK energy suppliers can charge on a standard tariff, reviewed roughly every three months. It sets the backdrop for how solar and heat pump savings are calculated, since it moves the price of the electricity (and gas) you're comparing against.
Payback period
How many years it takes for the savings from solar or a heat pump to add up to what you paid upfront, after any grant.
VAT relief
Solar panels and heat pumps (equipment and labour, installed together) currently qualify for 0% VAT in the UK under a temporary relief for energy-saving materials, running until 31 March 2027, after which the rate is due to revert to the 5% reduced rate under current rules.